17
Figure 9-1: A-5000 Receiver Battery Replacement
TECHNICAL SPECIFICATIONS
Frequency: 4.8 Hz Crystal Controlled
Input Sensitivity: 5 MV
Sensitivity Control: Automatic
Active/Reference Signal Sensitivity Logarithmic: 0 − 120
Linear: 0 − 999
Battery: 9 V NEDA 1604 or equivalent
Battery Life: 100 hr. continuous use
Battery Test: Automatic at power ON for 3 sec.
Weight: 4.4 lb (2.0 kg)
Dimensions: 32” H x 22” W x 1” D
(81 cm H x 56 cm W x 2.5 cm D)
Operational Temp: -4°F − +120°F
(-20°C − +50°C)
APPENDIX
APWA Marking Colors
The following color markings have been established by the American Public Works Association (APWA):
Conductor Color
Electric power lines, cables, or conduits Red
Communication lines, cables, Conduits, CATV Orange
Gas, oil, petroleum, or other gaseous materials Yellow
Sewers, storm and sanitary, drain lines Green
Water, irrigation, or slurry lines Blue
If you have any questions regarding marking requirements or procedures in the United States, please call your local One Call
Center. International customers: please check with your local regulatory authorities or utility companies required color markings
may vary between different countries.