For detailed specifications go to www.Amprobe.eu
B Loop resistance measurement up to 265 V
B Line resistance measurement up to 440 V
B Prospective short circuit current measurement
B RCD measurements (contact voltage, trip time,
trip current - ramp method)
B Low Ohm measurement
B Insulation measurement with 100, 250, 500 V
B Voltage and frequency measurement
B Rotary field test
B Integrated memory for approx. 500
measurement values
B Standard, built-in IR RS-232 interface for
transferring measurement data to the PC
B Software es control for recording test results
is available as option
B Integrated socket test with contact electrode
to enable the user to quickly establish
incorrectly installed sockets and/or protective
conductor failures
B Clear and large LCD providing the user with
an optimum visual indication of both test
values and limits
B Auto power off
B Measurement of loop resistance and
prospective short circuit current measurement
without tripping the RCD
TELARIS 0100-PLUS
Multifunction Installation Tester
FEATURES
Display LCD, 3½-digit, 1999 Digits
Measurement Ranges
Resolution
Voltage
1...440 V 1V AC/DC
Frequency
10...99,9 Hz 0,1 Hz
Loop Impedance
0,15…19,99./199,9/1999 Ω 0,01/0,1/1 Ω
Prospective Short
Circuit Current
Input Voltage Range
Test Current
Line Resistance
0,10 A...1,7 kA
195...264 V 50/60 Hz
approx. 4,6 A (at 230 V)
0,15…19,99Ω/199,9/1999 Ω
0,01A...0,1 kA
0,01/0,1/1 Ω
Prospective Short
Circuit Current
Input Voltage Range
Test Current
Loop Resistance
(without tripping the RCD)
0,10 A...2,7 kA
195...440 V 50/60 Hz
approx. 4,6 A (at 230 V)
0,5...19,99Ω/199,9/1999 Ω
0,01A...0,1 kA
0,01/0,1/1Ω
Prospective Short
Circuit Current
Input Voltage Range
Test Current
Insulation Resistance
Test Voltage
Low Ohm Measurement
Test Current
0,50 A...0,5 kA
195...264 V 50/60 Hz
approx. 5 mA (at 230 V)
0,05...19,99/199,9 MΩ
100, 250, 500 V DC
0,05...19,99/199,9/1999 Ω
> 200 mA DC
0,01A...0,1kA
0,01/0,1 MΩ
0,01/0,1/1 Ω
RCD-Test Nominal
currents
selective:
Measurement
Functions
Contact Voltage
Earth Resistance
Tripping Time
Tripping Current
10, 30, 100, 300, 500mA
0,5 x 30mA, 5 x 30mA
100, 300, 500mA
Contact voltage,
trip time, Tripping current test with
ramp method
1...63 V
10…1999
Ω
/19,99 kΩ
1...500 ms
40...140% of IN (in 10% steps)
1
Ω
/0,01 kΩ
1 ms
Rotary Field Test
Input Voltage Range
Data memory
Interface
Safety complying with
Measurement category
Pollution Degree
Protection Degree
Power Supply
100...440 V 50/60 Hz
approx. 500 values
IR-RS-232
IEC61010, EN61010, DIN VDE 0411/
IEC61557, EN61557, DIN VDE 0413
CAT III/440V
2
IP 40
6 x 1,5 V, IEC LR6
RCD Analyser
B Swift and easy test of RCDs (also time delayed
types)
B Measurement of contact voltage without
tripping the RCD
B Measurements of trip time and trip current
– ramp method
B RCD analysis for test of all RCD parameters
B Display of earth resistance
B Integrated memory for approx. 100
measurement values
B Standard, built-in IR/RS-232 interface for
transferring measurement data to the PC
B Software es control for recording test results is
available as option
B Curve shape to be selected for RCDs of Type
AC, A, B
B Test current for pre-selection x 0.5 / x 1 / x 2
and x 5
B Integrated socket test with contact electrode
to enable the user to quickly establish
incorrectly installed sockets and/or protective
conductor failures
B Clear and large LCD providing the user with
an optimum visual indication of both test
values and limits
B Auto power off
TELARIS RCD-TEST
RCD Analyser
FEATURES TELARIS RCD-TEST
Display digit, LCD, 1999 Digits Measurement ranges /
Resolution
Nominal test current 10 / 30 / 100 / 300 / 500mA/ 1 A
time delayed: 100mA/ 300mA/ 500 mA / 1 A
Contact voltage 0.6...70 V / 0.1 V
Tolerance (-0%...+10%) + 6 Digits
Trip time 2...1999 ms / 1 ms
Tolerance ±(2%+2 Digits)
Test current type AC, DC, DC pulse
Earth resistance
0.01...1999 Ω / 1 Ω
Tolerance ±(10%+10 Digits)
Mains voltage 230 V +10% / -15%
Data memory approx. 100 measurements
Interface IR/RS-232 interface-adapter
Protection class II (double insulated)
Safety complying with IEC61010/EN61010/DIN VDE 0411
IEC61557/EN61557/DIN VDE 0413
Measurement category CAT III / 300 V
Pollution degree 2
Protection degree IP 50
Power supply 6 x 1.5 V, IEC LR6
For detailed specifications go to www.Amprobe.eu