6
FREQUENCY
Range Accuracy Resolution
10Hz
± ( 0.1%+5 )
0.01Hz
100Hz 0.1Hz
1000Hz 1Hz
10kHz 10Hz
100kHz 100Hz
1000kHz 1kHz
10MHz 10kHz
Sensitivity: sine wave 0.6V RMS (10MHz: 1.5V RMS)
Overload protection: 250V DC or AC RMS
DUTY CYCLE
0.1% ~ 99.9%: ± (2.0%+2) Frequency lower than 10kHz
Sensitivity: sine wave 0.6V RMS
Overload protection: 250V DC or AC RMS
TEMPERATURE (AM-240 ONLY)
• Accuracyspecificationisrelativetotheuser-adjustabletemperatureoffset,and
assumes ambient temperature stable to ± 1°C.
• Forambienttemperaturechangesof±5°C,ratedaccuracyappliesafter1hour.
• Doesnotincludeerrorofthethermocoupleprobe
Range Accuracy Resolution
-58ºF ~ +1292ºF +/-(1% + 3ºF)
1° /1°F
-50ºC ~ +700ºC +/-(1% + 2ºC)
Overload protection: 250V DC or AC RMS