10
AC Voltage
Range Accuracy
50 Hz – 60 Hz
4.000 V, 40.00 V, 400.0 V ±(2.0%+5 dgt)
60 Hz – 500 Hz
4.000 V, 40.00 V, 400.0 V ±(3.0%+5 dgt)
50 Hz – 500 Hz
600 V ±(3.5%+5 dgt)
Input Impedance: 10 M, 30 pF nominal
CMRR: > 60 dB @ DC to 60 Hz, Rs=1 k
Capacitance
Range
1
Accuracy
2
500.0 nF, 5.000 µF, 50.00 µF, 500.0 µF, 3000 µF
3
±.(3.5%+6 dgt
4
)
1
Additional 50.00 nF range accuracy is not specified
2
Accuracies with film capacitor or better.
3
Updates > 1 minute on large values
4
Specified with battery voltage above 2.8 V (half full battery). Accuracy decreases gradually to
12% at low battery warning voltage of approx 2.4 V